Release Notes EdWin ------------------------------------------ 5.16 15.01.2020-------------------------------------------- New: Analog+Thermo+Video data acquisition with DT modules and Matrix Vision cameras. ------------------------------------------ 5.15 27.06.2016-------------------------------------------- Fixed: DATaRec4: Switch Single Ended - Symetrical for DIC6L doesn't function always. ------------------------------------------ 5.14 24.06.2016-------------------------------------------- Fixed: DATaRec4: Abnormal termination if SMM measurement is selected but not medium plugged to LMF. ------------------------------------------ 5.13 17.06.2016-------------------------------------------- New: DATaRec4: SGU9 can set sensor supply voltage in if not in sensor mode. ------------------------------------------ 5.12 16.06.2016-------------------------------------------- New: DATaRec4: CAN module with more than 4 or 6 defined channels generats DLL error message. ------------------------------------------ 5.11 9.05.2016-------------------------------------------- New: DATaRec4: CAN data stream can be recorded binary ----------------------------------------- 5.10 21.01.2016-------------------------------------------- Fixed: DATaRec4: Calibration takes care of changing range ------------------------------------------ 5.09 13.01.2016-------------------------------------------- Fixed: DATaRec4: Overflow marking of real measurement range (in orange) doesn't consider sign ------------------------------------------ 5.08 18.11.2015-------------------------------------------- Fixed: DATaRec4: SGU9: Bridge power and type is not written to data header ------------------------------------------ 5.07 12.11.2015-------------------------------------------- Fixed: DATaRec4: SGU9: support of sensitivity <0 and/or nominal value < 0 ------------------------------------------ 5.06 03.11.2015-------------------------------------------- Fixed: DATaRec4: SGU9 can operate together with camera ------------------------------------------ 5.05 23.10.2015-------------------------------------------- Fixed: DATaRec4: DIC6L shows error message with programming DIC6L It doesn't support single ended/symetrical input. ------------------------------------------ 5.04 5.10.2015-------------------------------------------- Fixed: DATaRec4: DIC24Plus with Filter HP 22Hz generates warning Fixed: DATaRec4: Calibration with SGU9 shows sometimes bouncing values on DVM ------------------------------------------ 5.03 17.09.2015-------------------------------------------- New: DATaRec4: Video clock also possible with SGU9 Strain gauge modul. ------------------------------------------ 5.02 7.09.2015-------------------------------------------- Fixed: DATaRec4: Since version 5.0 error if CAN module plugged. New: MH-USB32 Box und EbersPaecher FlexCard USB for millisecond precise synchronization of analog and CAN data acquisition. ------------------------------------------ 5.01 21.05.2015-------------------------------------------- Fixed: DATaRec4: different sample rate per modul + CAN module generates error ------------------------------------------ 5.00 08.06.2015-------------------------------------------- New: DATaRec4: Different sample rates per modul (or channel for GIM282) New: DATaRec4: Support for GIM282 module with CAN/FlexRay extension ------------------------------------------ 4.94 05.05.2015-------------------------------------------- Fixed: DATaRec4: Automatic fit of size of main window to size of the module windoe doesn't regard the minimum width of the dialogfiled above. Fixed: DATaRec4: Programming of DIC24Plus shows error message for Function DatGetRpm(...). ------------------------------------------ 4.94 12.03.2015-------------------------------------------- Neu: DATaRec4: Support for OUT6 Modul ------------------------------------------ 4.93 16.10.2014-------------------------------------------- Fixed: Sequential measurement: If the quotient of frames per file and subclock divider are not integer, merging of this files can cause a very little time shift on the file boundarys. ------------------------------------------ 4.92 31.07.2014-------------------------------------------- New: DATaRec4: CAlibration with inbuild DVM for DIC6B,DIC24 and SGU9 ------------------------------------------ 4.91 16.07.2014-------------------------------------------- Fixed: DATaRec4: CAN/FlexRay module shows the columns in wrong order. ------------------------------------------ 4.90 01.07.2014-------------------------------------------- Neu: DATaRec4: Columns Polarität, Label , and Range true can be hidden Neu: DATaRec4: One Module per page, selectable with tabs. ------------------------------------------ 4.84 13.11.2013-------------------------------------------- Fixed: DATaRec4: EdWin may abort (very seldom) after computer restart and call of EdWin with adapted modules. ------------------------------------------ 4.83 4.09.2013-------------------------------------------- Fixed: DATaRec4: DIC6L -> Symmetrical and single-ended mode is interchanged. ------------------------------------------ 4.83 23.08.2013-------------------------------------------- New: Übergabe der verbleibenden Messzeit und der CANBus-Auslastung an EwinView ------------------------------------------ 4.82 17.06.2013-------------------------------------------- New: Acquisition of real data (IEEE Floating Point) with CAN Bus ------------------------------------------ 4.81 13.06.2013-------------------------------------------- Fixed: DATaRec4: CAN4(F) module stand alone. Very seldom no more values will be displaed after some minutes. This depends on the computer. ------------------------------------------ 4.8 25.05.2013-------------------------------------------- New: EdWin support now DATaRec4 + Video with triggering. New: Changed synchronisation logic for DATaRec4 + Video. ------------------------------------------ 4.73 1.03.2013-------------------------------------------- Fixed: DATaRec4: Reset from sensor mode to normal normal mode doesn't reset unit to "V" ------------------------------------------ 4.72 18.02.2013-------------------------------------------- Fixed: DATaRec4: Fw.: 2.63 makes double start for synchronous data acquisition unnecessary Fixed: DATaRec4: RPM channel is stored with 16 Bit data width in file with 32 bit data width. ------------------------------------------ 4.71 12.12.2012-------------------------------------------- Fixed: DATaRec4: Programming of GPS can cause an error message depending on the revision of DATaRec4API ------------------------------------------ 4.70 03.12.2012-------------------------------------------- Fixed: DATaRec4: Program and calibrate with unassigned modules can cause an abnormal termination. ------------------------------------------ 4.69 30.11.2012-------------------------------------------- Fixed: DATaRec4: Changed channel calibration in firmware ------------------------------------------ 4.68 12.11.2012-------------------------------------------- New: EdWin ist fixed to core 1 and RTEWin to core 2 if multicore processor Fixed: DATaRec4: Load a configuration with DIC24 shows sometinmes a DIC24DC. ------------------------------------------ 4.67 24.10.2012-------------------------------------------- New: DATaRec4: Destination module will be marked blue during assigning it via drag&drop from the module finder. ------------------------------------------ 4.66 22.10.2012-------------------------------------------- Fixed: DATaRec4: Click on Errorlist after programing can cause a program termination if warnings are included. Neu: DATaRec4: Headerzeile for module has blue background ------------------------------------------ 4.65 19.10.2012-------------------------------------------- Fixed: DATaRec4: DIC24PLUS ICP channel 6-24 becaus error DC mode of the first 6 channels. Fixed: DATaRec4: DIC24PLUS,DIC6: can't set channel to DC coupling if channel was settled to ICP in a previous setting. Fixed: Copy marked channels with keyboard (CTRL+C) can cause an error. ------------------------------------------ 4.64 17.10.2012-------------------------------------------- New: DATaRec4: ICP + 10V für DIC24 and DIC24PLUS modul will be supported with a warning message. New: DATaRec4: Display if measurement range wanted > measurement range true ------------------------------------------ 4.63 11.10.2012-------------------------------------------- Fixed: DATaRec4: Trigger with RPM channels doesn't function properly. Fixed: DATaRec4: 1. RPM value in measurement is setted to 0. Fixed: DATaRec4: New DLL allows querry of channel programming ready before start of measurement. ------------------------------------------ 4.62 25.09.2012-------------------------------------------- Neu: Unplugged or unrecognized dongle doesn't set EdWin into demo mode no longer. New: DATaRec4: Support SMM Trigger ------------------------------------------ 4.61 14.09.2012-------------------------------------------- New: DATaRec4: MIC6 Modul will be supported New: DATaRec4: New DATaRec4api.dll New: DATaRec4: Restart EdWin and DATaRec4 hardware after switching between USB/FireWire or Ethernet or changing the ethernet ip adress is no more necessary. New: DATaRec4: Unrecognized system opens dialog for retry or offline mode. ------------------------------------------ 4.55 06.08.2012-------------------------------------------- Fixed: DATaRec4: Modul serial number for CAN modul will not be displayed in table header. ------------------------------------------ 4.54 11.07.2012-------------------------------------------- New: DATaRec4: Support for DATaRec4 + Video cameras with auto synchronisation ------------------------------------------ 4.53 03.07.2012-------------------------------------------- New: DATaRec4: Annotation block will be written too into folder C:\lmf ------------------------------------------ 4.52 02.07.2012-------------------------------------------- Fixed: DATaRec4: Extended annotation block of Firmware 2.54 is supported ------------------------------------------ 4.51 22.06.2012-------------------------------------------- Fixed: Driver from Vector doesn't support extended Can id (29 Bit) by default ------------------------------------------ 4.50 19.06.2012-------------------------------------------- Fixed: Driver for Multichoice Hardware doesn't support extended Can id (29 Bit) ------------------------------------------ 4.49 19.06.2012-------------------------------------------- Fixed: Expanded column width for CAN Id (Extended CAN Id has 9 digits at maximum) ------------------------------------------ 4.48 17.04.2012-------------------------------------------- Fixed: DATaRec4: DIC24DC will not be showed as DC Modul. ------------------------------------------ 4.47 3.04.2012-------------------------------------------- Fixed: DATaRec4: Changing a measurement without skipping to another field allows to start measurement without programming. That can generate errors. ------------------------------------------ 4.46 26.03.2012 -------------------------------------------- New: Support for DT ECON series ------------------------------------------ 4.45 28.02.2012-------------------------------------------- Fixed: DATaRec4: Annotation Block > 32K will not be stored in ch10 files. Compression now lowers block size. ------------------------------------------ 4.44 20.01.2012-------------------------------------------- Fixed: DVM for Data Translation cards shows wrong value for -5 -> 5 V range. ------------------------------------------ 4.43 29.11.2011-------------------------------------------- Fixed: DATaRec4: Prog+Calibration of active channels announces itself as ready to fast. ------------------------------------------ 4.42 15.11.2011 -------------------------------------------- New: Timeout for missing ethernet connection is faster. ------------------------------------------ 4.41 14.10.2011 -------------------------------------------- Fixed: DATaRec4: DIC24DC - Although the module only knows DC as Counplingmode , you can choose between AC and ICP. ------------------------------------------ 4.40 07.10.2011 -------------------------------------------- New: From the list of sensor in SignalDB several sensors can be transferred to EdWin by drag & drop New: DATaRec4: Cut, Copy and Paste in the table. New: Change name, unit, label, measurement range, coupling, filter setting for all selcted channels ------------------------------------------ 4.28 01.09.2011 -------------------------------------------- New: OEBB Kalibriermode switch off displays a messagebox. ------------------------------------------ 4.27 15.08.2011 -------------------------------------------- New: OEBB Calibration mode. ------------------------------------------ 4.26 11.08.2011 -------------------------------------------- Fixed: CAN Motorola Format > 16 doesn't work right. ------------------------------------------ 4.25 18.07.2011 -------------------------------------------- Fixed: DATaRec4: RPM measurement n 24Bit mode doesn't run properly. ------------------------------------------ 4.24 15.07.2011 -------------------------------------------- New: DATaRec4: DIC24 Plus Module is supported. ------------------------------------------ 4.23 7.07.2011 -------------------------------------------- Fixed: DATaRec4: "Timeout while waiting for channel update busy" DATaRec4 new driver dll 9.7.12 ------------------------------------------ 4.22 21.06.2011-------------------------------------------- Fixed: Baudrate for CAN is fixed to 500kB ------------------------------------------ 4.21 15.06.2011-------------------------------------------- Fixed: Language switch with Windows 7 doesn't function properly. ------------------------------------------ 4.20 21.02.2011 -------------------------------------------- New: DATaRec4: Software now suppoprts 24 bit resolution of A/D converters. ------------------------------------------ 4.19 18.02.2011 -------------------------------------------- New: DATaRec4 new driver dll ------------------------------------------ 4.18 13.02.2010-------------------------------------------- Fixed: DATaRec4: DIC24 ICP mode is not progammable if one of the deactivated channels is programmed to 10Volt rangea. ------------------------------------------ 4.17 10.02.2010-------------------------------------------- New: DATaRec4: Library now supports activation/deactivation of hardware channels. ------------------------------------------ 4.16 20.11.2010-------------------------------------------- Fixed: EdWin for MC overwrites the entered input range with the AD Wandler Bereich ------------------------------------------ 4.15 11.10.2010-------------------------------------------- Neu: DATaRec4: Increased refreshrate for realtime display (EWinView). ------------------------------------------ 4.14 18.09.2010-------------------------------------------- Fixed: SignalDB rework ------------------------------------------ 4.13 18.08.2010-------------------------------------------- Fixed: DATaRec4: Driver for USB is errornous. ------------------------------------------ 4.12 06.08.2010-------------------------------------------- Fixed: Audio recording with the built-in sound card of the PC has a measurement delay after repeated measurement start ------------------------------------------ 4.11 26.07.2010-------------------------------------------- Fixed: CAN und FlexRay signals with data length > 16 Bit gives wrong measurement values. Neu: Sort the FIBEX table ------------------------------------------ 4.1 15.07.2010-------------------------------------------- New: FIBEX 3.0 support in EdWin and SignalDB New: Definable timeout for interrupted data transfer (only for DATaRec4) ------------------------------------------ 4.0 08.07.2010-------------------------------------------- New: Support for CAN FlexRay Module (CAN4F) from HEIM. New: Support for extended CAN (29Bit Id) in the SignalDB. ------------------------------------------ 3.9 01.06.2010-------------------------------------------- New: Interruption of data transfer from DATaRec4 to PC will be reported and data will be saved. ------------------------------------------ 3.9 09.05.2010-------------------------------------------- Fixed: Sometimes EdWin for DATaRec4 modules calculates a sample frequency with a small rounding error (+-10Hz). The measurement will be done with this frequency and this frequency is also logged in the data header. This means that the measured data sets are ok. ------------------------------------------ 3.8 05.05.2010-------------------------------------------- Fixed: EdWin with RtEWin runtime dongle starts in demo mode. ------------------------------------------ 3.7 27.04.2010-------------------------------------------- Fixed: SignalDB will not be termonated when EdWin terminates. Fixed: DATaRec4 CAN Module as first module behind LMF gives no values. ------------------------------------------ 3.68 15.04.2010-------------------------------------------- Fixed: SignalDB generates abnormal termination in EdWin, dependent from the kind of sensor data base. ------------------------------------------ 3.67 14.04.2010-------------------------------------------- Fixed: Start of measurement with a DEBU modul generates an abnormal termination in EdWin. ------------------------------------------ 3.66 08.04.2010-------------------------------------------- Fixed: If the dongle is transferred to the PC and winter-summer time change happens EwinView doesn't recognizes the dongle. ------------------------------------------ 3.65 23.03.2010-------------------------------------------- Neu: MH-USB Box + GPS with external GPS receiver (GPS mouse). ------------------------------------------ 3.64 10.03.2010-------------------------------------------- New: DATaRec4 modules + GPS with external GPS receiver (GPS mouse). ------------------------------------------ 3.53 24.02.2010-------------------------------------------- New: Video sampling is now possible with pretrigger. ------------------------------------------ 3.62 17.11.2009-------------------------------------------- Fixed: EdasWin allows licence transfer from dongle to computer, too if only a EdWin/EWinView dongle is plugged and errornous reporting the transfer to be successful. ------------------------------------------ 3.61 16.11.2009-------------------------------------------- Fixed: Some problems with dongle transfer (to computer and back) if timzone will be changed. Too with change between summertime and wintertime. ------------------------------------------ 3.60 09.11.2009-------------------------------------------- Fixed: EdWin for CSM CAN Modules programs Modules no more. ------------------------------------------ 3.59 28.10.2009-------------------------------------------- New: Command line parameters /start und /exit for automatic stzart and exit of EdWin ------------------------------------------ 3.58 15.10.2009-------------------------------------------- Fixed: EdWin don't pass the data file name to a waiting EdasWin. ------------------------------------------ 3.57 13.10.2009-------------------------------------------- Fixed: USB Interface without LMF generates an abnormal termination in EdWin. ------------------------------------------ 3.56 1.10.2009-------------------------------------------- Fixed: Mark channel then delete module from view generates an abnormal termination. ------------------------------------------ 3.55 29.09.2009-------------------------------------------- New: Transfer dongle to PC transfers the license for EDwin and EWinView together. ------------------------------------------ 3.54 22.09.2009-------------------------------------------- New: Control panel on LMF module of DATaRec4 systeme is locked as long as EdWin is activ. ------------------------------------------ 3.53 21.09.2009-------------------------------------------- New: Unknown DATaRec4 modules will be recognized. An error message occurs. ------------------------------------------ 3.52 18.09.2009-------------------------------------------- Fixed: Some Errors with ch10 files. ------------------------------------------ 3.50 09.09.2009-------------------------------------------- New: Support for SMM of DATaRec4 modules. New: Calibration of active channels of DATaRec4 modules or all modules. New: Measurement without storing deleted in toolbar. Input option is now in the dialog box. ------------------------------------------ 3.40 07.08.2009-------------------------------------------- Fixed: Sequential measuremnent can give wrong error message "File exists, delete?". ------------------------------------------ 3.39 10.07.2009-------------------------------------------- Fixed: EdWin for DATaRec4 don't recognize filter options for modules (new DATaRec4Api.dll). ------------------------------------------ 3.38 09.07.2009-------------------------------------------- Fixed: EdWin for DATaRec4 can hang if it is terminated regularly. ------------------------------------------ 3.37 29.06.2009-------------------------------------------- Fixed: Wrong EDWinViewDATAREC.zip on our homer page. Since 20.6.2009 ------------------------------------------ 3.36 18.06.2009-------------------------------------------- Fixed: EdWin trigger without function. (since 4.32) ------------------------------------------ 3.35 05.06.2009-------------------------------------------- Fixed: EdWin for CAN use wrong clkrate (since Vers. 3.30 files > 4 GByte) ------------------------------------------ 3.34 04.05.2009-------------------------------------------- Fixed: EdWin for MC transfers new channels to EWinView only after starting measurement. ------------------------------------------ 3.33 24.05.2009-------------------------------------------- New: Demo mode via Internet. ------------------------------------------ 3.32 12.05.2009 ------------------------------------ Fixed: Enter 0 as sample rate can generate a program termination. ------------------------------------------ 3.31 12.05.2009 ------------------------------------ Fixed: Parameter file (extension = edw ) with file length = 0 generates program termination. ------------------------------------------ 3.30 2.04.2009 ------------------------------------ New: Data files > 4GBytes will be supported. ------------------------------------------ 3.25 16.03.2009 ------------------------------------ Fixed: Autostart EdWin entry is missing in the english optinons menu. ------------------------------------------ 3.24 09.02.2009 ------------------------------------ New: Extension for MH's own amplifier box ------------------------------------------ 3.23 03.02.2009 ------------------------------------ Fixed: Video CAN Trigger can not be programmed (since version 3.22) ------------------------------------------ 3.22 01.02.2009 ------------------------------------ Fixed: Video CAn Trigger doesn't run on CAN Port 2 ------------------------------------------ 3.21 09.12.2008 ------------------------------------ New: Video streaming for CAN Fixed: HEIM CAN Modul: User input in last line of Port doesn't generate a new empty lines after edititing. Fixed: Correktur of some translation errors. ------------------------------------------ 3.20 05.12.2008 ------------------------------------ New: Autostart measurement after program start with and without storing the measurement data Fixed: Highest samplingrate for DATAREC modules will not be checked ------------------------------------------ 3.19 11.11.2008 ------------------------------------ New: Autostart measurement after program start. ------------------------------------------ 3.18 10.11.2008 ------------------------------------ Fixed: Triggered measurement without trigger but stopped by user, generates sometime a measurement file without measurement points. Fixed: SignalDB: Copie & edit doesn't function for Sensor lcation numbers Fixed: SignalDB: Empty sensor location number shifts table content after reload ------------------------------------------ 3.17 5.11.2008 ------------------------------------ New: Version no. of DLL will be displayes in scan dialog. New: UTC Time in data header ------------------------------------------ 3.16 31.10.2008 ------------------------------------ New: Sensor mode can only be switched off in the main menü ------------------------------------------ 3.15 29.10.2008 ------------------------------------ Fixed: DEBU Modul can't serve ICP sensors ------------------------------------------ 3.14 ------------------------------------------------ New: On/Off for selected channels Fixed: CAN channels with highest bit set to high, will not be processed correct. New: Increased size of "ewdll" buffers (*4) ------------------------------------------ 3.13 ------------------------------------------------ Fixed: Start EdWin without CSM Hardware weites wron clockrate in configuration file. After next load the clockrate is wrong. Fixed: Copy - paste with more than 1 channel doesn't run. ------------------------------------------ 3.12 ------------------------------------------------ New: Increased accuray for RPM channels. ------------------------------------------ 3.11 ------------------------------------------------ New: Support for RPM channels of DataRec4 modules. ------------------------------------------ 3.10 ------------------------------------------------ Fixed: Rangedefinition in modul mode (no sensors) overwrite range filed with highest possible range. ------------------------------------------ 3.09------------------------------------------------- New: Triggered nmeasurement without trigger, but stopped by hand, generates a errornous data file. ------------------------------------------ 3.08------------------------------------------------- New: New sensor data base